Busca de Produtos



PRODUTOS
Verifies on electrical installation and power quality analysis on single and three phase systems
Cód. GSC57
PRINCIPAIS CARACTERÍSTICAS
Integrated instrument for complete verifies on electrical installation and power quality analysis on single and three phase systems
Mais Detalhes do Produto

 

GSC57 is the most complete model of the entire meters designed to verifies both on electrical installations according to IEC61557, BS7671, VDE0100 and power quality on generic three phase systems. Flexibility of this meter consents using by installers, technicians, engineers and testers of electrical plants and equipment. GSC57 performs, from the other things, a fault Loop Impedance with high resolution (0.1 mOhm) nearly power transformer thanks use of IMP57 optional accessory. As logger meter, GSC57 can recording all values of electrical parameters (Voltages, Currents, Powers, Power Factory, Energies, etc.), performing harmonic analysis of Voltages and Currents (up to 49-th order) and consents a supply voltages quality analysis (sags, spikes, breaks). With optional probes GSC57 can also performing measures and recordings of environmental parameters as Temperature, Humidity, Illumination (Lux), Sound Level and Leakage currents very important for troubleshooting problem of RCDs wrong tripping. Each measure can stored inside instrument memory, recalled on instrument display and transferred to  PC using the management standard software in way to create a professional relation which will improve the quality of work.

Function

  • Continuity on protective conductors with 200 mA
  • Continuity on protective conductors with10 A
  • Insulation resistance
  • Tripping time and current of RCDs (type A, AC, general and selective)
  • Line and Loop impedance and prospective short circuit current
  • Loop impedance with high resolution (with IMP57 optional accessory)
  • Global Earth Resistance without RCDs tripping
  • Earth resistance with 3-wire and 2-wire methods
  • Ground resistivity with 4-wire method
  • Contact voltage
  • Phase rotation
  • TRMS measure and recording (Voltages, Currents, Powers, etc)
  • Harmonic analysis of voltage and current up to the 49th order
  • Voltage anomalies (sags, spikes, breaks) with a 10ms resolution
  • Measurement and recording to leakage current to earth
  • Measurement and recording of Temperature  (°C/°F), Humidity (HR%)
  • Measurement and recording Illuminations (Lux)
  • Save results inside memory
  • Recall measured test at display
  • Interface for PC communication
  • Auto Power OFF
  • Backlight

 

Accessories

STANDARD

  • C2033X : Cable 3 wires with Shuko plug
  • KITGSC5 : Set 4 cables + 4 alligator clips + 2 test leads
  • KITTERRNE : Set 4 cables + 4 metal probes
  • C5700 : Power cord for test 10A
  • TOPVIEW2006 : Windows software + optical/USB cable C2006
  • BORSA2051 : Soft carrying bag
  • User manual
  • ISO9000 calibration certificate

 

Av Dr Luis Arrobas Martins 229, Vila Friburgo - 04781-000 - Sao Paulo - SP - (11) 5103-2057 - intelengi@intelengi.com.br